During testing, the Philips PML9009 performed best in the factory "Filmmaker" mode, which we evaluated across both SDR and HDR content. A key characteristic observed in this mode is the EOTF curve’s behaviour in HDR content and gamma settings in SDR, designed to enhance image accuracy. However, the PML9009 presented noticeable issues, particularly with white balance, as a pronounced red dominance created a yellow tint across the entire image. This affected skin tones and white areas, with faces and whites appearing unnaturally warm. The colour shift was confirmed through the "ColourChecker" palette, where colours leaned towards warmer shades.
In the gamma analysis, responsible for image contrast, we noticed considerable inaccuracies early on. Our measured values spiked above the reference, causing dark scenes to lose detail and merge visually up to about 10% screen brightness. Following this, the values dropped below the target line, further degrading contrast—an area already challenging for this model.
In HDR content, the white balance remained similarly flawed, and the EOTF curve also restricted brightness levels, resulting in a dim, muted image. Colour inaccuracies were even more pronounced here, with lower luminance levels causing large deviations from accurate colours, which were clearly visible on the error graph, often exceeding acceptable limits. While aiming for cinematic quality, this mode ultimately fell short in delivering balanced colour and contrast fidelity.
In Filmmaker mode our R85H sample performed adequately in SDR, but a few things immediately showed up in the measurements. In the white balance, as brightness increased more red crept in while blue decreased. As a result, the brighter parts of the image had a slightly too warm tint. On top of that, gamma only held to the target value at the start. It then gradually fell, making most of the image a bit too bright. The combination of the two also affected colors — errors grew especially in the brighter, more saturated samples. It didn’t look bad, but for Filmmaker mode we expected a bit more accuracy. Interestingly, in HDR our unit handled things noticeably better. White balance was much more even and, for most of the range, the individual RGB components stayed close together. Only in the brightest areas did red begin to fall short, causing the white point to shift slightly. The EOTF curve looked very good, tracking the target luminance values across almost the entire range. That doesn’t mean HDR colors were perfect. The ColorChecker still shows some deviations, particularly in some of the more saturated hues, but the errors are clearly smaller than in SDR.