During testing, the Philips PML9009 performed best in the factory "Filmmaker" mode, which we evaluated across both SDR and HDR content. A key characteristic observed in this mode is the EOTF curve’s behaviour in HDR content and gamma settings in SDR, designed to enhance image accuracy. However, the PML9009 presented noticeable issues, particularly with white balance, as a pronounced red dominance created a yellow tint across the entire image. This affected skin tones and white areas, with faces and whites appearing unnaturally warm. The colour shift was confirmed through the "ColourChecker" palette, where colours leaned towards warmer shades.
In the gamma analysis, responsible for image contrast, we noticed considerable inaccuracies early on. Our measured values spiked above the reference, causing dark scenes to lose detail and merge visually up to about 10% screen brightness. Following this, the values dropped below the target line, further degrading contrast—an area already challenging for this model.
In HDR content, the white balance remained similarly flawed, and the EOTF curve also restricted brightness levels, resulting in a dim, muted image. Colour inaccuracies were even more pronounced here, with lower luminance levels causing large deviations from accurate colours, which were clearly visible on the error graph, often exceeding acceptable limits. While aiming for cinematic quality, this mode ultimately fell short in delivering balanced colour and contrast fidelity.
The colour reproduction in the LG NANO82T in Filmmaker mode, while the best factory setting available, does have flaws. The primary issue lies in white balance, where measurements reveal a drop in the level of blue. This shifts towards yellow hues, making the image warmer than intended. Such deviations prevent natural colour reproduction, especially in scenes with white or neutral backgrounds. For instance, in Star Wars, where numerous elements should appear white, the colours deviate noticeably. The Color Checker test corroborates this, showing some shades "escaping" into others, further highlighting the lack of accurate colour rendering.
In terms of contrast, the gamma graph analysis showed a drop to 2.1, falling short of the optimal 2.4. This leads to darker parts of the image appearing brighter, reducing depth and dynamism. Additionally, the EOTF curve, which governs brightness reproduction, shows a slight spike at the start. This can result in an excessive brightness boost in the brightest areas, causing a loss of detail in very bright scenes.